SilverNet NDR-240-48 network switch component Power supply
xOut of Stock
Contact your account manager
- 240W 48V DC
- 63x125.2x113.5 mm
SKU #: SIL NDR-240-48
EAN #: 5060693980633
UNSPSC #: 43222612
- Universal AC Input / Full Range
- Protections from: Short Circuit / Overload / Over Voltage
- Cooling by Free Air Convection
- Can be installed on DIN Rail TS-35/7.5 or 15
- 100% Full Load Burn In Test
- UL 508 Industrial Control Equipment Approved
- EN61000-6-2 (EN500820-2) Industrial Immunity Level
- Slim design for easy installation
Features | |
---|---|
Product type | Power supply |
Mean time between failures (MTBF) | 230200 h |
LED indicators | Power |
Product colour | Black |
Certification | Heavy industry level, criteria A, EAC TP TC 020 Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC UL508, TUV EN62368-q, EAC TP TC 004 approved;(meet EN60204-1) |
Power protection features | Over voltage, Overheating, Overload |
DIN rail mounting | Yes |
Colour | |
Product colour | Black |
Technical details | |
Mean time between failures (MTBF) | 230200 h |
LED indicators | Power |
Height | 113.5 mm |
Compliance industry standards | EN6100-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2, -3, EAC TP TC 020 |
Package width | 100 mm |
Package weight | 960 g |
Package height | 150 mm |
Package depth | 158 mm |
Warranty period | 1 year(s) |
Network | |
Compliance industry standards | EN6100-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2, -3, EAC TP TC 020 |
Power | |
AC input voltage | 90-264 V |
AC input frequency | 47 - 63 Hz |
Total power | 240 W |
Maximum current | 5 A |
Inrush current | 35 A |
DC voltage range | 48 - 55 V |
DC output voltage | 48 V |
Voltage tolerance | 1% |
Ripple & noise | 150 mVpp |
Certificates | |
---|---|
Certification | Heavy industry level, criteria A, EAC TP TC 020 Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC UL508, TUV EN62368-q, EAC TP TC 004 approved;(meet EN60204-1) |
Operational conditions | |
Storage temperature (T-T) | -40 - 85 °C |
Storage relative humidity (H-H) | 10 - 95% |
Operating temperature (T-T) | -20 - 70 °C |
Operating relative humidity (H-H) | 20 - 90% |
Weight & dimensions | |
Weight | 1 kg |
Height | 113.5 mm |
Width | 63 mm |
Depth | 125.2 mm |
Packaging data | |
Package width | 100 mm |
Package weight | 960 g |
Package height | 150 mm |
Package depth | 158 mm |
Logistics data | |
Warranty period | 1 year(s) |
UK Trade Tariff code | 85044095 |
The SIL NDR-240-48 PSU is a 240W, 48V, 5A DIN rail power supply designed for installation on TS-35/7.5 or TS-35/15 mounting rails. Its 63mm width helps to conserve space when installed inside cabinets.
It is ideal for use with SilverNet Series 7 Industrial network switches.
The SIL NDR-240-48 features a metal housing that improves power dissipation and boasts an operational efficiency of up to 90%. It can function in temperatures ranging from -20°C to 70°C and comes with protections against short circuits, overload, and overvoltage.
It is ideal for use with SilverNet Series 7 Industrial network switches.
The SIL NDR-240-48 features a metal housing that improves power dissipation and boasts an operational efficiency of up to 90%. It can function in temperatures ranging from -20°C to 70°C and comes with protections against short circuits, overload, and overvoltage.
Features | |
---|---|
Product type | Power supply |
Mean time between failures (MTBF) | 230200 h |
LED indicators | Power |
Product colour | Black |
Certification | Heavy industry level, criteria A, EAC TP TC 020 Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC UL508, TUV EN62368-q, EAC TP TC 004 approved;(meet EN60204-1) |
Power protection features | Over voltage, Overheating, Overload |
DIN rail mounting | Yes |
Colour | |
Product colour | Black |
Technical details | |
Mean time between failures (MTBF) | 230200 h |
LED indicators | Power |
Height | 113.5 mm |
Compliance industry standards | EN6100-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2, -3, EAC TP TC 020 |
Package width | 100 mm |
Package weight | 960 g |
Package height | 150 mm |
Package depth | 158 mm |
Warranty period | 1 year(s) |
Network | |
Compliance industry standards | EN6100-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2, -3, EAC TP TC 020 |
Power | |
AC input voltage | 90-264 V |
AC input frequency | 47 - 63 Hz |
Total power | 240 W |
Maximum current | 5 A |
Inrush current | 35 A |
DC voltage range | 48 - 55 V |
DC output voltage | 48 V |
Voltage tolerance | 1% |
Ripple & noise | 150 mVpp |
Certificates | |
---|---|
Certification | Heavy industry level, criteria A, EAC TP TC 020 Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC UL508, TUV EN62368-q, EAC TP TC 004 approved;(meet EN60204-1) |
Operational conditions | |
Storage temperature (T-T) | -40 - 85 °C |
Storage relative humidity (H-H) | 10 - 95% |
Operating temperature (T-T) | -20 - 70 °C |
Operating relative humidity (H-H) | 20 - 90% |
Weight & dimensions | |
Weight | 1 kg |
Height | 113.5 mm |
Width | 63 mm |
Depth | 125.2 mm |
Packaging data | |
Package width | 100 mm |
Package weight | 960 g |
Package height | 150 mm |
Package depth | 158 mm |
Logistics data | |
Warranty period | 1 year(s) |
UK Trade Tariff code | 85044095 |