This site uses cookies and other tracking technologies to assist with navigation and your ability to provide feedback, analyse your use of our site and services and assist with our promotional and marketing efforts. You can read more about this in our Privacy Policy.
APC Galaxy VS uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA 40000 W
xOut of Stock
Contact your account manager
- 40 kW
- 400 V
- for External Batteries
- Start-up 5 x 8
- 206 kg
SKU #: GVSUPS40KMHS
EAN #: 0731304418351
UNSPSC #: 39121011
Output power capacity | 40 kVA |
---|---|
Product colour | White |
Output power | 40000 W |
Form factor | Tower |
SKU | GVSUPS40KMHS |
EAN | 0731304418351 |
Manufacturer | APC |
Availability | Out of Stock |
PDF URLs |
View PDF |
Power | |
---|---|
Output power | 40000 W |
Input operation voltage (min) | 340 V |
Input operation voltage (max) | 460 V |
Output operation voltage (max) | 400 V |
Maximum current | 72 A |
Output voltage Total Harmonic Distortion (THD) | 1% |
Input current Total Harmonic Distortion (THD) | 3% |
Crest factor | 2.5:1 |
Output power capacity | 40 kVA |
Charging current | 136 A |
ECO mode | Yes |
Performance | |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Noise level | 68 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Output power | 40000 W |
Input operation voltage (min) | 340 V |
Input operation voltage (max) | 460 V |
Output operation voltage (max) | 400 V |
Maximum current | 72 A |
Output voltage Total Harmonic Distortion (THD) | 1% |
Noise level | 68 dB |
Input current Total Harmonic Distortion (THD) | 3% |
Crest factor | 2.5:1 |
Audible alarm(s) | Yes |
Output power capacity | 40 kVA |
ECO mode | Yes |
Input frequency | 40 - 70 Hz |
Package type | Box |
Charging current | 136 A |
Battery | |
Battery voltage | 576 V |
Battery technology | Lithium-Ion (Li-Ion) |
Charging current | 136 A |
Design | |
International Protection (IP) code | IP21 |
Form factor | Tower |
Product colour | White |
Cooling type | Active |
Certification | EN/IEC 62040-1, EN/IEC 62040-2, FCC, IEC 60721-4-2, UL 1778 |
Built-in fan | Yes |
Control type | Touch |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -25 - 55 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 10 - 80% |
Operating altitude | 0 - 1005.84 m |
Technical details | |
---|---|
Output frequency | 50/60 Hz |
Bypass | Static |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Package type | Box |
Package width | 640 mm |
Package depth | 990 mm |
Package height | 1680 mm |
Weight | 206 kg |
Width | 520 mm |
Package weight | 250 kg |
Height | 1485 mm |
Depth | 847 mm |
Packaging data | |
Quick installation guide | Yes |
Package type | Box |
Package width | 640 mm |
Package depth | 990 mm |
Package height | 1680 mm |
Package weight | 250 kg |
Certificates | |
Certification | EN/IEC 62040-1, EN/IEC 62040-2, FCC, IEC 60721-4-2, UL 1778 |
Other features | |
Bypass | Static |
Packaging content | |
Quick installation guide | Yes |
Highly efficient, easy-to-deploy 40kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and halogen-free cables. Marine certified.
Includes: Dust filter, EcoStruxure IT ready (UPS), Installation guide, Integrated network management, Power modules ship installed, Start-up service.
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
EcoStruxure IT Expert
From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries.
Multiple levels of service offers
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.
Modular UPS design
Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
High efficiency in double conversion mode
Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Robust operation
No power derating in kW up to 40°C or 104°F.
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Compatible with Galaxy Lithium-ion Battery Cabinets
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Galaxy VS UPSs for external batteries are compatible with Galaxy Lithium-ion Battery Cabinets.
Compact UPS
High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.
Flexible DC bus
Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.
Embedded Network Management Card
Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.
Parallel-redundant capability
Powers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.
Built-in backfeed protection
Full built-in backfeed contactor ensures that no electricity is sent back to the grid.
Parallel-capacity capability
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Includes: Dust filter, EcoStruxure IT ready (UPS), Installation guide, Integrated network management, Power modules ship installed, Start-up service.
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
EcoStruxure IT Expert
From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries.
Multiple levels of service offers
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.
Modular UPS design
Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
High efficiency in double conversion mode
Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Robust operation
No power derating in kW up to 40°C or 104°F.
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Compatible with Galaxy Lithium-ion Battery Cabinets
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Galaxy VS UPSs for external batteries are compatible with Galaxy Lithium-ion Battery Cabinets.
Compact UPS
High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.
Flexible DC bus
Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.
Embedded Network Management Card
Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.
Parallel-redundant capability
Powers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.
Built-in backfeed protection
Full built-in backfeed contactor ensures that no electricity is sent back to the grid.
Parallel-capacity capability
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Power | |
---|---|
Output power | 40000 W |
Input operation voltage (min) | 340 V |
Input operation voltage (max) | 460 V |
Output operation voltage (max) | 400 V |
Maximum current | 72 A |
Output voltage Total Harmonic Distortion (THD) | 1% |
Input current Total Harmonic Distortion (THD) | 3% |
Crest factor | 2.5:1 |
Output power capacity | 40 kVA |
Charging current | 136 A |
ECO mode | Yes |
Performance | |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Noise level | 68 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Output power | 40000 W |
Input operation voltage (min) | 340 V |
Input operation voltage (max) | 460 V |
Output operation voltage (max) | 400 V |
Maximum current | 72 A |
Output voltage Total Harmonic Distortion (THD) | 1% |
Noise level | 68 dB |
Input current Total Harmonic Distortion (THD) | 3% |
Crest factor | 2.5:1 |
Audible alarm(s) | Yes |
Output power capacity | 40 kVA |
ECO mode | Yes |
Input frequency | 40 - 70 Hz |
Package type | Box |
Charging current | 136 A |
Battery | |
Battery voltage | 576 V |
Battery technology | Lithium-Ion (Li-Ion) |
Charging current | 136 A |
Design | |
International Protection (IP) code | IP21 |
Form factor | Tower |
Product colour | White |
Cooling type | Active |
Certification | EN/IEC 62040-1, EN/IEC 62040-2, FCC, IEC 60721-4-2, UL 1778 |
Built-in fan | Yes |
Control type | Touch |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -25 - 55 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 10 - 80% |
Operating altitude | 0 - 1005.84 m |
Technical details | |
---|---|
Output frequency | 50/60 Hz |
Bypass | Static |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Package type | Box |
Package width | 640 mm |
Package depth | 990 mm |
Package height | 1680 mm |
Weight | 206 kg |
Width | 520 mm |
Package weight | 250 kg |
Height | 1485 mm |
Depth | 847 mm |
Packaging data | |
Quick installation guide | Yes |
Package type | Box |
Package width | 640 mm |
Package depth | 990 mm |
Package height | 1680 mm |
Package weight | 250 kg |
Certificates | |
Certification | EN/IEC 62040-1, EN/IEC 62040-2, FCC, IEC 60721-4-2, UL 1778 |
Other features | |
Bypass | Static |
Packaging content | |
Quick installation guide | Yes |