This site uses cookies and other tracking technologies to assist with navigation and your ability to provide feedback, analyse your use of our site and services and assist with our promotional and marketing efforts. You can read more about this in our Privacy Policy.
APC SY125K250D-NB uninterruptible power supply (UPS) Double-conversion (Online) 500 kVA 500000 W
xOut of Stock
Contact your account manager
- 500kVA
- 500kW
- 400-552V
- 40/70Hz
- IP20
SKU #: SY125K250D-NB
UNSPSC #: 39121011
SKU | SY125K250D-NB |
---|---|
Manufacturer | APC |
Availability | Out of Stock |
Power | |
---|---|
Input power factor | 0.99 |
Output power | 500000 W |
Input operation voltage (min) | 400 V |
Input operation voltage (max) | 552 V |
Output operation voltage (min) | 400 V |
Output operation voltage (max) | 480 V |
Efficiency | 96% |
Output voltage Total Harmonic Distortion (THD) | 3% |
Input current Total Harmonic Distortion (THD) | 5% |
Output power capacity | 500 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Low battery alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Response time | 2 ms |
LED indicators | Yes |
Power protection features | Overload, Short circuit |
Noise level | 54 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Low battery alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Input power factor | 0.99 |
Response time | 2 ms |
Output power | 500000 W |
Input operation voltage (min) | 400 V |
Input operation voltage (max) | 552 V |
Output operation voltage (min) | 400 V |
Output operation voltage (max) | 480 V |
Efficiency | 96% |
Power protection features | Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 3% |
Noise level | 54 dB |
Input current Total Harmonic Distortion (THD) | 5% |
Audible alarm(s) | Yes |
Output power capacity | 500 kVA |
Input frequency | 40/70 Hz |
Ports & interfaces | |
SmartSlot | Yes |
AC outlet types | Hard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G) |
RS-232 ports | 1 |
Design | |
International Protection (IP) code | IP20 |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | cUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, OSHPD, UL 1778, UL 60950-1, UL Listed |
Display type | LCD |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -30 - 70 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 1000 m |
Non-operating altitude | 0 - 15000 m |
Technical details | |
Output frequency | 50/60 Hz |
Certificates | |
Certification | cUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, OSHPD, UL 1778, UL 60950-1, UL Listed |
Packaging content | |
Quick installation guide | Yes |
Manual | Yes |
Weight & dimensions | |
Package width | 1870 mm |
Package depth | 1270 mm |
Package height | 2150 mm |
Weight | 864 kg |
Width | 1200 mm |
Package weight | 1000 kg |
Height | 1991 mm |
Depth | 1070 mm |
Packaging data | |
Quick installation guide | Yes |
Manual | Yes |
Package width | 1870 mm |
Package depth | 1270 mm |
Package height | 2150 mm |
Package weight | 1000 kg |
SY125K250D-NB Features
- Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable
- A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission-critical environments. Multiple UPSs can be installed in parallel for ultra-efficient system redundancy or up to 2MW of power protection. Parallel installations with custom switchgear and installations using a 3rd-party maintenance bypass panel require the APC Symmetra PX250/500 Third Party Switchgear Kit for breaker monitoring and EPO functionality.
- Includes: Assembly service, Installation guide, Network Management Card, Start-Up Service, User Manual
- Symmetra PX 125kW Scalable to 250kW w/o Bypass, Distribution or Batteries-Parallel Capable
- A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission-critical environments. Multiple UPSs can be installed in parallel for ultra-efficient system redundancy or up to 2MW of power protection. Parallel installations with custom switchgear and installations using a 3rd-party maintenance bypass panel require the APC Symmetra PX250/500 Third Party Switchgear Kit for breaker monitoring and EPO functionality.
- Includes: Assembly service, Installation guide, Network Management Card, Start-Up Service, User Manual
Power | |
---|---|
Input power factor | 0.99 |
Output power | 500000 W |
Input operation voltage (min) | 400 V |
Input operation voltage (max) | 552 V |
Output operation voltage (min) | 400 V |
Output operation voltage (max) | 480 V |
Efficiency | 96% |
Output voltage Total Harmonic Distortion (THD) | 3% |
Input current Total Harmonic Distortion (THD) | 5% |
Output power capacity | 500 kVA |
Performance | |
Audible alarm modes | Alarm when on battery, Low battery alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Response time | 2 ms |
LED indicators | Yes |
Power protection features | Overload, Short circuit |
Noise level | 54 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
Audible alarm modes | Alarm when on battery, Low battery alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Input power factor | 0.99 |
Response time | 2 ms |
Output power | 500000 W |
Input operation voltage (min) | 400 V |
Input operation voltage (max) | 552 V |
Output operation voltage (min) | 400 V |
Output operation voltage (max) | 480 V |
Efficiency | 96% |
Power protection features | Overload, Short circuit |
Output voltage Total Harmonic Distortion (THD) | 3% |
Noise level | 54 dB |
Input current Total Harmonic Distortion (THD) | 5% |
Audible alarm(s) | Yes |
Output power capacity | 500 kVA |
Input frequency | 40/70 Hz |
Ports & interfaces | |
SmartSlot | Yes |
AC outlet types | Hard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G) |
RS-232 ports | 1 |
Design | |
International Protection (IP) code | IP20 |
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | cUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, OSHPD, UL 1778, UL 60950-1, UL Listed |
Display type | LCD |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -30 - 70 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 1000 m |
Non-operating altitude | 0 - 15000 m |
Technical details | |
Output frequency | 50/60 Hz |
Certificates | |
Certification | cUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, OSHPD, UL 1778, UL 60950-1, UL Listed |
Packaging content | |
Quick installation guide | Yes |
Manual | Yes |
Weight & dimensions | |
Package width | 1870 mm |
Package depth | 1270 mm |
Package height | 2150 mm |
Weight | 864 kg |
Width | 1200 mm |
Package weight | 1000 kg |
Height | 1991 mm |
Depth | 1070 mm |
Packaging data | |
Quick installation guide | Yes |
Manual | Yes |
Package width | 1870 mm |
Package depth | 1270 mm |
Package height | 2150 mm |
Package weight | 1000 kg |