APC SRVPM10KRI uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 10000 W
xOut of Stock
Contact your account manager
- 10 kVA
- 10 kW
- 220-240
- 40/70Hz
- 58 dB
SKU #: SRVPM10KRI
EAN #: 0731304343417
UNSPSC #: 39121011
Automatic internal bypass
Pure static bypass switch without bridging contactor securing a fast and reliable transfer to and from bypass, rated for 125% nominal load.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
EPO
Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emergency situation.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Allows the user to manage the UPS functions, schedule automatic shutdown and monitor the power grid occurrences through an interactive interface that ensures an easy and intuitive monitoring.
Management Software
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Management Software
Allows you to easily monitor your utility power and manage your UPS.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
High efficiency
High efficiency rates that remain stable even at lower operating power levels
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent Card Slot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity
Provides management of the UPS via a serial port.
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent Card Slot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Pure static bypass switch without bridging contactor securing a fast and reliable transfer to and from bypass, rated for 125% nominal load.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
EPO
Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emergency situation.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Allows the user to manage the UPS functions, schedule automatic shutdown and monitor the power grid occurrences through an interactive interface that ensures an easy and intuitive monitoring.
Management Software
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Management Software
Allows you to easily monitor your utility power and manage your UPS.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
High efficiency
High efficiency rates that remain stable even at lower operating power levels
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent Card Slot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity
Provides management of the UPS via a serial port.
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent Card Slot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
SKU | SRVPM10KRI |
---|---|
EAN | 0731304343417 |
Manufacturer | APC |
In Stock | N |
Power | |
---|---|
Output power | 10000 W |
Input operation voltage (min) | 110 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 600 J |
Emergency Power Off (EPO) | Yes |
Crest factor | 3:1 |
Output power capacity | 10 kVA |
ECO mode | Yes |
Performance | |
Audible alarm modes | Alarm when on battery, Overload alarm, Low battery alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Auto-restart | Yes |
LED indicators | Yes |
Noise level | 58 dB |
Audible alarm(s) | Yes |
Features | |
Audible alarm modes | Alarm when on battery, Overload alarm, Low battery alarm |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Auto-restart | Yes |
Output power | 10000 W |
Input operation voltage (min) | 110 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 600 J |
Emergency Power Off (EPO) | Yes |
Noise level | 58 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 10 kVA |
ECO mode | Yes |
Input frequency | 40/70 Hz |
Ports & interfaces | |
USB port | Yes |
Serial interface | Yes |
SmartSlot | Yes |
Battery | |
Battery voltage | 192 V |
Automatic battery test | Yes |
Design | |
---|---|
LED indicators | Yes |
Product colour | Black |
Certification | CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2 |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Weight & dimensions | |
Package width | 600 mm |
Package depth | 760 mm |
Package height | 240 mm |
Weight | 16 kg |
Width | 438 mm |
Package weight | 20 kg |
Height | 86.5 mm |
Depth | 615 mm |
Packaging data | |
Cables included | USB cable |
Manual | Yes |
Package width | 600 mm |
Package depth | 760 mm |
Package height | 240 mm |
Package weight | 20 kg |
Certificates | |
Certification | CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2 |
Packaging content | |
Cables included | USB cable |
Manual | Yes |