APC Smart-UPS VT 40 kVA 32000 W

Login for pricing
xOut of Stock
Contact your account manager
  • Smart-UPS VT
  • 400V
  • 32 kW / 40 kVA
  • 301kg
  • black
Add to Compare
SKU #: SUVTR40KHS
EAN #: 0731304242802
UNSPSC #: 39121011
More Information
Output power capacity 40 kVA
Product colour Black
Output power 32000 W
SKU SUVTR40KHS
EAN 0731304242802
Manufacturer APC
Availability Out of Stock
Power
Output power32000 W
Emergency Power Off (EPO)Yes
Output power capacity40 kVA
Battery
Battery typeVRLA
Battery recharge time3 h
Performance
Noise level67 dB
Audible alarm(s)Yes
Features
Output power32000 W
Emergency Power Off (EPO)Yes
Noise level67 dB
Audible alarm(s)Yes
Output power capacity40 kVA
Input frequency40/70 Hz
Ports & interfaces
Number of output IEC jumpers12
Design
Product colourBlack
CertificationC-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-50 - 40 °C
Operating altitude0 - 999.9 m
Non-operating altitude0 - 15000 m
Technical details
Harmonized System (HS) code85078000
Weight & dimensions
Weight301 kg
Package weight370.9 kg
Packaging data
Package weight370.9 kg
Certificates
CertificationC-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
Other features
InterfaceSmart-Slot
Battery typeVRLA
Output connections- Hard Wire 5-wire (3PH + N + G) - IEC 320 C19
Input connection typeHard Wire 5-wire (3PH + N + G)
Dimensions (WxDxH)600 x 1075 x 1995 mm
Nominal input voltage400 V
Resettable circuit breakers Enables a quick recovery from overload events. Field-replaceable power distribution panel Ensures compatibility with equipment that has different plug types. Multiple cable-entry points Provides flexibility of UPS placement in the room and easy access to install cabling to the terminal blocks. Locking cabinet Prevents unauthorized access to the UPS. Dual mains input Increases availability by allowing the UPS to be connected to two separate power sources. Scalable runtime Allows additional run time to be quickly added as needed. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Battery modules connected in parallel Delivers higher availability through redundant batteries. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Battery replacement without tools Allows quick, easy battery replacement. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Shippable with modules installed Enables pre-installation UPS staging and testing and faster installation. Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Network manageable Provides remote management of the UPS over the network. InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure® Manager. LCD display Alpha-Numeric Display which displays system parameters and alarms. Audible alarms Provides notification of changing utility power and UPS conditions. Programmable frequency Ensures compatibility with different input frequencies. LED status indicators Quickly understand unit and power status with visual indicators. SmartSlot Customize UPS capabilities with management cards. Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Manual maintenance bypass Reduces installation costs by eliminating the need for an external mechanical bypass. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. Cold-start capable Provides temporary battery power when the utility power is out.
Power
Output power32000 W
Emergency Power Off (EPO)Yes
Output power capacity40 kVA
Battery
Battery typeVRLA
Battery recharge time3 h
Performance
Noise level67 dB
Audible alarm(s)Yes
Features
Output power32000 W
Emergency Power Off (EPO)Yes
Noise level67 dB
Audible alarm(s)Yes
Output power capacity40 kVA
Input frequency40/70 Hz
Ports & interfaces
Number of output IEC jumpers12
Design
Product colourBlack
CertificationC-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-50 - 40 °C
Operating altitude0 - 999.9 m
Non-operating altitude0 - 15000 m
Technical details
Harmonized System (HS) code85078000
Weight & dimensions
Weight301 kg
Package weight370.9 kg
Packaging data
Package weight370.9 kg
Certificates
CertificationC-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
Other features
InterfaceSmart-Slot
Battery typeVRLA
Output connections- Hard Wire 5-wire (3PH + N + G) - IEC 320 C19
Input connection typeHard Wire 5-wire (3PH + N + G)
Dimensions (WxDxH)600 x 1075 x 1995 mm
Nominal input voltage400 V